Eaton PDUMNH16HVAT - PDUMNH16HVAT
Write a Review
Write a Review
Eaton
Eaton PDUMNH16HVAT - PDUMNH16HVAT
MSRP:
Now:
$849.58
Was:
(You save
)
- Brand
- Eaton
- SKU:
- PDUMNH16HVAT
- UPC:
- Availability:
- Within 2 Days Shipping
The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant powe
The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 15 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).
Primary and Secondary Inputs for Power Redundancy
- Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
- IEC309 16A Blue (2P+E) inputs with 10-ft. (3.05 m) cords connect to separate primary and secondary single-phase power sources
- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
- Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)
Automatic Transfer Switching
- Dynamic solid-state (TRIAC) automatic transfer switching
- Switches to secondary power source if primary source fails or becomes unstable
- 1-5 ms transfer time ensures uninterrupted operation of connected equipment
- Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display with LEDs
- Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
- LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
- Real-time load/current data with billing-grade accuracy (+/- 1 percent)
- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
Broad Communications Compatibility
- HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
- 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
- PDUMNH16HVAT 3.8kW Single-Phase 200-240V ATS/Monitored PDU
- Rack-mounting brackets
- Owners manual
OVERVIEW
UPC Code | 037332186560 |
PDU Type | Monitored; Auto-Transfer Switch |
INPUT
Input Phase | Single-Phase |
PDU Input Voltage | 200; 208; 220; 230; 240 |
Recommended Electrical Service | Two single-phase 16A 200-240V circuits |
Maximum Input Amps | 16 |
Maximum Input Amps Details | Agency de-rated to 16A continuous |
PDU Plug Type | (2) IEC-309 16A BLUE (2P+E) |
Input Cord Details | Set of two inputs connect to separate PRIMARY and SECONDARY power sources |
Input Cord Length (m) | 3.05 |
OUTPUT
Output Capacity Details | 3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum |
Frequency Compatibility | 50 / 60 Hz |
Output Receptacles | (1) IEC309 16A BLUE (2P+E) |
Output Nominal Voltage | 200-240V |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display | Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor |
Front Panel LEDs | Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status |
Switches | ENTER and MODE switches toggle the digital display to display all reported information |
Current Measurement Accuracy (Amps) | +/-1% |
Voltage Measurement Accuracy (Volts) | +/-1% |
Power Measurement Accuracy (Watts) | +/-1% |
PHYSICAL
Material of Construction | Metal |
Form Factors Supported | 1U rackmount |
Minimum Required Rack Depth (cm) | 44.45 |
PDU Form Factor | Horizontal (1U) |
Shipping Dimensions (hwd / cm) | 18.29 x 52.07 x 53.59 |
Shipping Weight (kg) | 7.57 |
Unit Dimensions (hwd / cm) | 4,4 x 43 x 35,6 |
Unit Weight (kg) | 7.87 |
ENVIRONMENTAL
Operating Temperature Range | 32° to 104°F (0° to 40°C) |
Storage Temperature Range | -22° to 122°F (-30° to 50°C) |
Relative Humidity | 5% to 95% non-condensing |
Operating Elevation (ft.) | 0-10,000 |
Operating Elevation (m) | 0-3000 |
COMMUNICATIONS
PowerAlert Software | LX Platform Interface: PowerAlert Device Manager |
Communications Cable | Micro-USB- to-USB A configuration/console Access cable |
Network Monitoring Port | RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
Network Compatibility | 10 Mbps; 100 Mbps (Fast Ethernet) |
FEATURES & SPECIFICATIONS
High Availability PDU Features | Auto-Transfer Switching |
STANDARDS & COMPLIANCE
Product Certifications | EN 60950-1 |
Product Compliance | RoHS; CE (Europe) |
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) | 2-year limited warranty |
0 Reviews Hide Reviews Show Reviews
Eaton
Eaton CSHANDLEKIT2 - CSHANDLEKIT2
MSRP:
Now:
$222.77
Was:
Tech SpecsSpecificationsManufacturerTripp Lite by EatonManufacturer Part NumberCSHANDLEKIT2<
Add to Cart
The item has been added
Eaton
Eaton CSC32ACW - CSC32ACW
MSRP:
Now:
$1,302.48
Was:
Eaton CSC32ACW - CSC32ACWTrionics Distributor of Tripp Lite By Eaton,MPN: CSC32ACW Tech SpecsSpecificationsManufacturer Part NumberCSC32ACW
Add to Cart
The item has been added
Eaton
Eaton DMCS3270XPBB - DMCS3270XPBB
MSRP:
Now:
$2,986.62
Was:
Eaton DMCS3270XPBB - DMCS3270XPBBTrionics Distributor of Tripp Lite By Eaton,MPN: DMCS3270XPBB Tech SpecsSpecificationsManufacturer Part NumberDMCS3270XPBB</
Add to Cart
The item has been added
Eaton
Eaton DDR0710SC - DDR0710SC
MSRP:
Now:
$23.21
Was:
The DDR0710SC Full-Motion Universal Tablet Desk Clamp attaches to your desk, table or workstation, allowing you to mount your tablet above or below it and free up valuable workspace. Upside-down...
Add to Cart
The item has been added
Eaton
Eaton DWF60100XX - DWF60100XX
MSRP:
Now:
$136.38
Was:
The VESA-compliant DWF60100XX Fixed Wall Mount allows you to mount your flat-panel television, monitor or other display on the wall. Ideal for home theaters, classrooms, boardrooms, hotels, bars and...
Add to Cart
The item has been added