R.M Young 43502 COMPACT ASPIRATED RADIATION SHIELD, 115/230 V
- Brand
- R.M Young
- SKU:
- 43502
- Availability:
- In Stock
Model 43502 Aspirated Radiation Shield provides accurate ambient air temperature measurements in a unique low cost, small size, and conservatively rated instrument. Radiation errors are less than 0.2° C RMS with the shield exposed to solar radiation of 1000 W/m2. The triple wall shield employs three concentric downward facing intake tubes and a canopy shade to isolate the temperature sensor from direct and indirect radiation. The temperature sensor mounts vertically in the center of the intake tubes.
Model 41342 Temperature Probe and Model 41382 RH/ Temperature Probe fit directly in a mounting ring within the shield. The convenient Model 41390 Junction Box, which is available separately, will accept other RTD, thermocouple, or thermistor type sensors with sheath diameters up to 10 mm (0.4 in) and 150 mm (6.0 in) in length. Other types of sensors up to 20 mm diameter can also be accommodated in the shield. Longer probes may be used with the optional Model 43476 Extender Tube. The small shield size reduces the surface area exposed to incoming radiation during the day, significantly reducing the amount of heat that needs to be washed away from the intake tubes. Errors from outgoing radiation at night are similarly reduced. A continuous duty brushless DC blower pulls ambient air into the shield and across the temperature sensor. Flow rate at the sensor is 5 to 11 m/s, depending upon sensor size. Brush-less electronic commutation of the blower motor is achieved using dependable solid-state circuitry. The blower is designed for continuous duty of
more than 80,000 hours (9 years) at 25° C (77° F).
The blower housing and shield assembly are made from white UV stable plastic, which provides high reflectivity, low heat conduction, and maximum weatherability. The mounting bracket with a plastic v-block and stainless steel U-bolt will accommodate a vertical mounting post of 25 to 50 mm (1 to 2 in) diameter and allows easy height adjustment.
The Model 43502 is ideally suited for lapse rate measurements. With identical shields and sensors at 2 m and 10 m levels, the temperature difference (delta T) can be measured with a relative accuracy of 0.05° C RMS under conditions of maximum solar radiation.
SPECIFICATIONS:
Sensor Types: Accommodates temperature and humidity sensors up to 24mm (0.9 in) diameter
Radiation Error
Ambient Temp: <0.2°C (0.4°F) RMS (@1000 W/m² intensity)
Delta T: <0.05°C (0.1°F) RMS with like shields equally exposed
Aspriation Rate: 5 to 11 m/s (16-36 fps) depending on sensor size
Power Requirement: 12-14 VDC@500 mA for blower
Tachometer Output: 135-150 Hz Nominal (With 41342 Temp Sensor Installed)
Operating Temp Range: -50° to +60° C. (-58° to +140° F.)
DIMENSIONS
Overall Height: 33 cm (13 in)
Overall Diameter: 20 cm (8 in)
Shield: 7 cm (2.7 in) dia. x 12 cm (4.7 in)
Blower Housing: 17 cm (6.7 in) dia. x 11 cm (4.3 in)
Mounting: V-Block and U-Bolt for vertical post or tower
member 25-50 mm (1.0-2.0 in) dia.
Weight | 8 lbs |
---|---|
Dimensions | 8 × 8 × 12 in |